ILC1-D AC Contactor manufacturer
TLC1-D AC Contactor model:
ILC1-D0910 Contactor,ILC1-D0901 Contactor,ILC1-D1210 Contactor,ILC1-D1201 Contactor,ILC1-D1810 Contactor,ILC1-D1801 Contactor,ILC1-D2510 Contactor,ILC1-D2501 Contactor,ILC1-D3210 Contactor,ILC1-D3201 Contactor,ILC1-D4011 Contactor,ILC1-D5011 Contactor,ILC1-D6511 Contactor,ILC1-D8011 Contactor,ILC1-D9511 Contactor,
1. ILC1-D AC Contactor Applications:
ILC1-D series AC contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz or 60Hz, rated current 95A, for making,breaking, frequent starting & controlling the AC motor. Combined with the auxiliary contact block, air dealer & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The products com-ply with IEC60947-4-1 standard.
2.NORMAL RUNNING AND INSTALLATION CONDITIONS
2.1 Ambient air temperature: -5°C-+40°C, the average value should not exceed +35°C within 24 hours.
2.2 Elevation: at most 2000m.
2.3 Atmospheric conditions: When the temperature at 40, the relative humidity of atomsphere should be at the most 50%. When at relatively low temperatures, it could have higher relative humidity. Monthly maximum relative humidity could be not more than 90%. Special measures should be taken due to occurrence of dews.
2.4 Class of pollution:Class 3
2.5 Installation category:III
2.6 Installation conditions: Degree of inclination between fitting surface and vertical surface should not exceed ±5°.
2.7 Impact shock: Product should be installed and used in the place where often shakes and impacts.
3. CONSTRUCTION FEATURES
3.1 Adopt building block system to mount auxiliary contactor block, air delay auxiliary contactor,
thermal overload relay and so on, which can be combined into multiple derived series product.
3.2 Contactor has the advantage of Small volume, light, low consumption, high life, good safety.
3.3 Main contactor below 32A has 1 N/C or 1 N/O, there is 1 N/C and 1 N/O above 40A. Contactor can be assembled with F4, F8 auxiliary contact or Time-delay block.
3.4 Contactor can not only use screw mounting, but also use 35mm\[CJX-09~95],75mm \[CJX-40~95] and2 x 35mm\[CJX-115~170] international standard Din-rail mounting.
4 .Main technical Parameter
Type |
ILC1-D09 |
ILC1-D12 |
ILC1-D18 |
ILC1-25 |
ILC1-D32 |
Rated working current (A) |
AC3 |
9 |
12 |
18 |
25 |
32 |
AC4 |
3.5 |
5 |
7.7 |
8.5 |
12 |
AC3 capacityof phase 3 squirrel-cage motor AC3(KW) |
220V |
2.2 |
3 |
4 |
5.5 |
7.5 |
380V |
4 |
5.5 |
7.5 |
11 |
15 |
415V |
4 |
5.5 |
9 |
11 |
15 |
440V |
4 |
5.5 |
9 |
11 |
15 |
660V |
5.5 |
7.5 |
10 |
15 |
18.5 |
Rated heat current(A) |
20 |
20 |
32 |
40 |
50 |
Electrical life |
AC4X104 |
20 |
20-15 |
20-7 |
15-7 |
15-7 |
AC3X106 |
2 |
2 |
2 |
2 |
2 |
Mechanical life 106 |
20 |
20 |
20 |
20 |
20 |
number of the contact |
3P+NO |
3P+NC |
Coil voltage(V) |
24 |
42 |
48 |
110 |
120 |
127 |
220 |
240 |
Frequency(Hz) |
50 |
B5 |
D5 |
E5 |
F5 |
- |
G5 |
M5 |
U5 |
50/60 |
B7 |
D7 |
E7 |
F7 |
- |
G7 |
M7 |
U7 |
Coil voltage(V) |
380 |
415 |
440 |
480 |
500 |
600 |
660 |
Frequency(Hz) |
50 |
Q5 |
N5 |
R5 |
- |
S5 |
- |
Y5 |
50/60 |
Q7 |
N7 |
R7 |
- |
- |
- |
- |
Type |
ILC1-D40 |
ILC1-D50 |
ILC1-D65 |
ILC1-D80 |
TLC1-D95 |
Rated working current (A) |
AC3 |
40 |
50 |
65 |
80 |
95 |
AC4 |
18.5 |
24 |
28 |
37 |
44 |
AC3 capacity of phase 3 squirrel-cage motor AC3(KW) |
220V |
11 |
15 |
18.5 |
22 |
25 |
380V |
18.5 |
22 |
30 |
37 |
45 |
415V |
22 |
25 |
37 |
45 |
45 |
440V |
22 |
30 |
37 |
45 |
45 |
660V |
30 |
33 |
37 |
45 |
45 |
Rated heat current(A) |
60 |
80 |
80 |
125 |
125 |
Electrical life |
AC4X104 |
10-7 |
7 |
7-6 |
7-5 |
7-5 |
AC3X106 |
2 |
2 |
1.6 |
1.6 |
1.6 |
Mechanical life 106 |
20 |
20 |
20 |
10 |
10 |
number of the contact |
3P+NC+NO |
Coil voltage(V) |
24 |
42 |
48 |
110 |
120 |
127 |
220 |
240 |
Frequency(Hz) |
50 |
B5 |
D5 |
E5 |
F5 |
- |
G5 |
M5 |
U5 |
50/60 |
B7 |
D7 |
E7 |
F7 |
- |
G7 |
M7 |
U7 |
Coil voltage(V) |
380 |
415 |
440 |
480 |
500 |
600 |
660 |
Frequency(Hz) |
50 |
Q5 |
N5 |
R5 |
- |
S5 |
- |
Y5 |
50/60 |
Q7 |
N7 |
R7 |
- |
- |
- |
- |